Calculation method and verification status
Noise Calculation is a free browser tool for exploring outdoor noise models. The project is developed by an environmental engineer with experience in environmental assessment. This page records what has been checked, what remains unverified and how to interpret the worked examples. Status updated 25 October 2026.
Start a free calculationCurrent propagation method
The current engine is a draft implementation identified as cnossos-eu:2021, core version 0.1.0. It follows the industrial-source propagation approach in Directive (EU) 2015/996, Annex II, with the 2021/1226 amendments. The examples use octave bands from 63 to 8000 Hz and explicitly state the chosen meteorology and operating period.
The engine calculates homogeneous and favourable propagation conditions. At core level, it can combine them by energy when a favourable-condition probability is supplied. The current browser adapter does not supply that probability and displays favourable conditions by default when no framework is selected. The examples therefore compare favourable levels. An assessment framework supplies periods and comparison criteria separately; selecting a country does not validate the propagation method or certify a report.
Verification status
The two worked propagation cases were run directly through the core on 25 October 2026. They produced no runtime warnings for those inputs. The method’s unverified status still applies: absence of a runtime warning is not proof of validation.
| Check | Status and meaning |
|---|---|
| Arithmetic checks | Energy addition and operating-time correction checked against direct mathematical calculation. |
| Worked propagation examples | Inputs and unrounded results generated by the current core; a reproducibility record, not an independent reference. |
| Automated software tests | Formula, geometry and integration checks exist in the project; passing tests alone does not establish engineering accuracy. |
| Independent implementation comparison | Not yet completed. No numerical accuracy or certification claim is made. |
| Atmospheric absorption formulation | Implemented, but verification against the referenced standard text remains outstanding. |
Assumptions and current limits
- Flat terrain; these examples contain no terrain profile.
- Omnidirectional source power in free-field conditions; take care not to double count a reflecting surface already included in source data.
- No lateral diffraction in the current method implementation.
- Examples use independent point sources and explicit operating durations; they are not a strategic mapping submission.
- Tonal or impulsive industrial noise, unsuitable source data and local assessment rules require qualified review beyond the worked examples.
Open data for reproducing the examples
All example equipment, spectra and layouts are synthetic. They do not describe a customer site, a measured product or a manufacturer guarantee. Files contain the complete metric inputs, settings, method metadata and unrounded outputs. Displayed tables round only for readability.
For a core reproduction, use the input dataclasses recorded in each JSON file with method cnossos-eu:2021 and core 0.1.0. The JSON files are reference data, not one-click browser imports. For a browser comparison, use a project without an assessment framework and preserve the geometry, heights, day operating minutes and default settings described in each article.
Report a reproducible discrepancy
Keep a copy of the exported calculation report and record the method and core version, source spectra, geometry, ground settings, meteorology and period. Describe the expected and actual value at one receiver with units. A small synthetic case is more useful for checking a numerical issue than an unexplained screenshot of a colour map.
Screening-level estimates do not replace an assessment by a qualified specialist. The implementation is not certified. References to ISO 9613-1:1993 in the method metadata identify a technical source; Noise Calculation is not affiliated with or endorsed by ISO.
Early preview. Screening-level estimates do not replace an assessment by a qualified specialist. The calculation is free and you can start without an account.