Sound power vs sound pressure: which input do you have?

Sound power describes a source’s acoustic output. Sound pressure describes the sound field at a location and depends on distance and surroundings. Both use decibels, so an input labelled only “dB” is incomplete. The examples below use ideal point-source geometry to make the distinction explicit.

Start a free calculation

Keep the reference quantity with the number

A sound pressure measurement at 10 m cannot be entered unchanged into a sound power field. Likewise, a broadband A-weighted value is not an octave-band spectrum. Keep the original data type and units instead of selecting whichever field accepts the number.

Keep the reference quantity with the number
QuantityReferenceWhat to record
Sound power level Lw1 picowattOperating condition, spectrum, whole source or per unit length/area
Sound pressure level Lp20 micropascalsMeasurement distance, position, environment and operating condition
A-weighted levelSame reference as its quantityWhether the value is Lw,A or Lp,A; A-weighting alone does not distinguish them

Example: from 10 m to 20 m

For a point source in an ideal free field with constant directivity and no additional losses, Lp,2 = Lp,1 − 20 log10(r2/r1). With Lp,A = 60 dBA at 10 m, the same source gives 53.9794 dBA at 20 m: a reduction of 6.0206 dB.

The ideal power-pressure relation is Lw = Lp + 20 log10(r/1 m) + 10 log10(Ω), with Ω in steradians. At 10 m, 60 dB of pressure corresponds to 90.99 dB of sound power for Ω = 4π, or 87.98 dB for Ω = 2π. Choosing a different radiation angle changes the inferred power.

These relations require a suitable far-field model and consistent frequency weighting. A reflective facade, a large nearby outlet, background noise or a directional source can invalidate the simple inference. Do not add a hemisphere correction again if a propagation model already includes the relevant reflecting ground.

One source and two pressure measurement locations at 10 m and 20 m
Geometrical spreading only; this is not the full propagation engine.

Example: adding sources and time

These are energy calculations. Do not add decibel values arithmetically or average 50 and 60 dB as if they were linear quantities. Apply each source’s duration before combining its period-average contribution with others.

Duration correction describes an equivalent average level. It does not reduce a maximum event level. The examples assume independent sources; coherent acoustic interference is outside this screening model.

Example: adding sources and time
OperationExpressionResult
Two equal independent levels of 50 dB10 log10(10^5 + 10^5)53.0103 dB
Half the assessment period10 log10(0.5)−3.0103 dB
Quarter of the assessment period10 log10(0.25)−6.0206 dB

Choose the input for your model

  1. Use measured or manufacturer octave-band sound power when available and appropriate to the model.
  2. For sound pressure input, retain the reference distance and radiation conditions and check whether conversion is defensible.
  3. If only an overall A-weighted value is available, document any assumed spectrum and its uncertainty.
  4. After entering the data, use a simple receiver arrangement to check units and expected distance behaviour before adding a complex site layout.

Early preview. Screening-level estimates do not replace an assessment by a qualified specialist. The calculation is free and you can start without an account.